This table lists all data files in chronological order. "SampleTemp" refers to the reading of the PT-1000 at the side of the sample holder. "cellPressure" is the water vapour pressure during the measurements. From this, in presence of ice, the temperature of the ice sample can be calculated which is given in the column "iceTemp". "dT" is the difference, or temperature offset, between sensor's reading and the ice samples temperature. The offset is due to the sensor being mounted away from the cooled spot of the sample were it experiences heating from warmer parts of the sample holder. The off-set is used to calibrate the temperature sensor and the resulting temperature during the experiments is given in the column "temperature". "relHum" is the relative humidity above (supercooled) liquid and "concBrine" is the concentration of a NaCl solution in mol/l in equilibrium with ice at the experimental temperature. "Area" is the integrated PE signal.